Skip to product information
1 of 5

Jag35

2000W Inverter MPPT Grid Tie Inverter for Battery/Solar

2000W Inverter MPPT Grid Tie Inverter for Battery/Solar

Regular price $333.38 USD
Regular price Sale price $333.38 USD
Sale Sold out
Shipping calculated at checkout.
Buy Now

Please read the description carefully.  This product is linked to a 3rd party affiliate.

 

2000w Standard Solar Power Grid Tie Inverter with Limiter sensor/clamp

Limiting 2kw Grid Tie Inverter, 45-90VDC, AC 220V 240V, LCD With Limiter-in Inverter

- DC 45V-90V
- AC 220V 230V 240V (auto selected )
- Internal Power Limiter built-in
- With Battery Discharge Function / Voltage Adjustable
 -Wi-Fi port (optional)
- Limiter sensor and clamp included (2 meter cable )

 

A product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are  reduced to insignificant levels, if not eliminated --- because in some countries, the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if  power is exported to the grid, thus the consumers will be charged for power even if it is given to the grid, and this is the problem.

With the 2nd generation GTIL, we integrated the limit function inside the GTI-We call this internal limiter.In this way,No additional limiter module is needed, reduced customer’s cost, more easier for installation.But in case customer install inverter far away from the main circuit breaker, we also enable the 2nd GTIL work with stand-alone limiter, we call this-external limiter.For sure, the inverter can work under normal Grid tie-no limit mode, just set on the nice LCD and save your setting. 

New upgraded firmware enable battery or solar limiter current and power model

User can set the maximum output power of inverter , this can make the inverter work at cooler condition as user want and extend the lifespan of the inverter . 
User can set kick in/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged .


Technical Data

Continuous Power Output
1950W                                                                
Peak Power Output
2000W
Input DC Voltage Range
 45V ~ 90V
Peak power tracking voltage                                        
 50V-90V
AC Output Voltage Range
190VAC ~ 260VAC
Output Frequency
46Hz~65Hz
Standby Power Consumption
<0.5W
Total Harmonic Distortion
<5%
Peak Inverter Efficiency
92%
MPPT Efficiency
99%
Power Factor
0.99
Output Wave Form
Pure Sine Wave
MPPT Function
Yes
Over Current Protection
Yes
Over Temperature Protection
Yes
Reverse Polarity Protection
Yes
Anti-Island Protection
Yes
Stackable
Yes
Weight ( Kg)
6kg
Dimensions (W x H x D) 
434x196x88 mm                                                             

 

 

a:  DC input, for solar panels connection

b:  Connector for external limiter

c:  Connector for internal limiter

d:  AC output, use AC cable to connect to home grid

 

1. Using Grid Tie Inverter With Limiter Model

 

2. Installation of GTIL With Internal Limiter

2.1) The Grid Tie Inverter with Limiter delivers only the power needed by the load and prevents delivering excess power hence avoids excess power in going back to the Grid.

2.2) The heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM). The LM continuously sampled the power needed by the load through the current sensor connected after the Main Circuit Breaker. The LM then will process the signal. It then sends signal to Grid Tie Inverter how much power to deliver to the load in real time.

2.3) The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its work automatically.

3.1) This installation is not require an additional limiter module,Installation is much easier.Clamp the current sensor cable to the hot wire to measure the current,the internal limiter will auto detect the load power and control the inverter output power,excess power will be well controlled.

3.2) External protective device including dc and ac SPD(Surge protection device),dc and ac breaker,etc is recommended to installed in the system.

4. Limiter Setting on the LCD of the inverter:

The GTIL include three working mode:Work as normal GTI without power limitation.Work under Internal limiter mode and Work under External limiter mode,Pls make your setting on the LCD and save it,details setting operation,pls read the GTI manual. 



5. Battery Discharge Power Mode

New upgraded firmware enable battery or solar limiter current and power model.

User can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter . 
User can set kick in/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged .

 

6. Limiter Module Specification

1. Clamp sensor- Max 100A

2. Wattmeter- Max 9999w

3. Terminal Block-Max 20A

4. Receptacle- max 2000w

5. Clamp sensor signal- 5v AC max mA

6. DC signal Cable- 5v DC, max mA

 
If the distance of meter and inverter is too long , you will need the External Limiter.

Note: The external limiter is not included in package

View full details