LED Lighting for Extreme Locations - Eaton Crouse-Hinds Champ® VMV
LED Lighting for Extreme Locations - Eaton Crouse-Hinds Champ® VMV
PLEASE READ THE DESCRIPTION CAREFULLY.
Shipping to USA only. No shipping to PO Boxes. No international shipping. Non-USA customers click here.
Unused condition, wet location lighting for hazardous locations! High/mid-bay lighting for harsh, hazardous and industrial environments, Eaton's Crouse-Hinds Champ® VMV LED Luminaires can deliver a lighting solution that performs reliably in even the worst operating conditions, all the while reducing your energy, maintenance and manpower costs. IP66 rated for protection against total dust ingress and high pressure liquid jets from any direction. Color temperature is bright white (5335 Lumens). UNV1 model accepts VAC and VDC input. Cat# VMV5L (LED light, less mount module module) and VMV9L (LED light, with stanchion mount module).
Available in 2 variants (choose from dropdown menu):
- VMV5L/UNV1 - 70W, No stanchion
- VMV9L/UNV1 - 100W, w/ stanchion
Applications
- For areas with mounting heights of 8-60 feet
- Oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, platforms, loading docks, tunnels, indoor/outdoor spotlighting, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present
- Locations requiring continuous and consistent light levels in extreme ambient temperatures
- Where extremely corrosive, wet, dusty, hot and/or cold conditions exist
- Classified and hazardous locations
Champ VMV benefits
- Instant illumination and restrike
- Cold temperature operation / no warm-up required
- Option for redundancy in drivers with multiple series circuits connected to each driver to avoid complete loss of illumination
- Easy installation - compact modular fixture attaches onto existing Champ mounting module
- Energy-efficient technology - up to 64% energy savings over HID fixtures
- Contains no mercury or other hazardous substances
- Shock- and vibration-resistant solid-state luminaires have no filaments or glass components that could break - greatly reduces the risk of premature failure
- Operating ambient: -40°C to 65°C (VMV3L-VMV11L models); -40°C to 55°C (VMV13L-VMV25L models)
Dimensions
- Height: 9 in
- Width: 10.18 in
- Length: 10.18 in
Electrical ratings
- Input voltage range, VAC: 120-277v
- Input voltage range, VDC: 127-250v (UNV1)
- Frequency: 50/60 Hz
- Watts: 64-70
- Input amps at 120-277 VAC: 0.35-0.16
- Min Power factor %: >0.90
- Total harmonic distortion (THD): <20%
- Nominal lumens ,Type V († Tolerance +/- 10%): 5,335
Fixture life
- Rated life of 60,000 hours @ 55°C operating ambient and 24/7 continuous operation for 365 days
- Economic life of 200,000 hours @ 25°C ambient
- L70 >300,000 hours @ 55°C
Standard materials
- Lamp housing and adapter - die cast aluminum with Corro-free™ epoxy powder coat
- Lens - heat- and impact-resistant glass
- Gaskets - silicone
- External hardware - stainless steel
- Factory-sealed, no external seals required
Qualifications and compliances
- DesignLights Consortium® Qualified
Certifications and compliances
- NEC and CE
- Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, nA nR; Class II, Groups E, F, G; Class III
- Zone 21 tb
- Simultaneous Presence
- Wet Locations, NEMA 4X, IP66
- UL Standards
- UL844; UL1598 Luminaires; UL1598A Marine; UL8750; UL50; UL50E
- CSA Standard
- cUL Listed to CSA Standard CSA C22.2 No. 137
- IEC
- IEC 60079-0:2011; IEC 60079-15:2010; IEC 60079-31:2008; IEC 60598-2-1:1979; IEC 60529:2001
- Ex nA nR IIC T* Gc -40 to +40
- Ex nA nR IIC T* Gc -40 to +55
- Ex nA nR IIC T* Gc -40 to +65
- Ex tb IIIC T*°C Db -40 to +40
- Ex tb IIIC T*°C Db -40 to +55
- Ex tb IIIC T*°C Db -40 to +65
- ATEX/CE
- EN 60079-0:2012; EN 60079-15:2010; EN 60079-31:2009; EN 60598-2-1:1989; EN 60929:1991 +A1:2001
- II 3 G Ex nA nR IIC T* Gc -40 to +40
- II 3 G Ex nA nR IIC T* Gc -40 to +55 • II 3 G Ex nA nR IIC T* Gc -40 to +65
- II 2 D Ex tb IIIC T*°C Db IP66 -40 to +40
- II 2 D Ex tb IIIC T*°C Db IP66 -40 to +55
- II 2 D Ex tb IIIC T*°C Db IP66 -40 to +65
Why LED?
- Useful life: Rated life is up to 60,000 hours of maintenance-free and safe operation
- Energy efficiency: LED average energy consumption is significantly less than traditional fluorescent and HID fixtures
- Start/restart time: Instant illumination versus 10 minute restrike time for HID
- Light quality: Higher color rendering compared to fluorescent and HID
- Environmental benefits: Mercury-free LED eliminates disposal costs and lower energy consumption for a smaller carbon footprint
Why Crouse-Hinds?
- Rugged design: Built to withstand extreme temperatures, vibration, water and dust
- High efficacy: Up to 124 lumens per watt (model dependent)
- Thermal management: Effective heat sinking ensures longer life
- Quality of light: Custom optics designed to maximize light distribution and intensity
- Versatile mounting: LED fixtures are compatible with Crouse-Hinds' HID installed base
PRODUCT VIDEO
___
These items are sold for DIY and Second Life purposes. Even when sold as “new”, “NOS”, or “like-new”, they may be in less than perfect condition. If you buy a product from us and then realize you don't have, or don't want to acquire, the tool(s) or information needed to make our product(s) work for your specific build, this does not constitute valid grounds for replacements, exchanges or refunds. You are responsible for doing your due diligence before making any purchases.